  sequential timer quick reference guide quick reference guide sequential timers ST-10/ST-10m1/st-6m1/ST-10m2 electronic automation (p) ltd p. b. # 6414, yelahanka, bangalore - 560064 phones: 0091 - 080 - 8567561 / 8567562 fax : 080 - 8567129 e-mail : eaplindia@vsnl.com url : www.eaplindia.com www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide thank you for purchasing eapl?s sequential timer. this instruction manual describes every aspect of installation, set-up, and operation of the sequential timer. if you run into difficulties and need technical assistance, feel free to call our technical support at (080) 8567561 available between 9 am ? 5:30pm ist or visit our web site at www.eaplindia.com. eapl, an iso 9001 company, leaders in timer technology brings to you a new range of micro controller based programmable timers. high reliability, accuracy, compactness are some of the striking design features. uncompromising quality with cost effectiveness has been the watchword at eapl. for customer use enter below the serial number which is located on the timer cabinet. retain this information for future reference. model no: serial no: batch no: date of purchase: purchase point: x sequential timer - 1 no. x quick reference guide note: please acknowledge that we reserve the right to make changes in product performance or specifications without prior notice. also please note that we bear no responsibility for mistakes, misprints or omissions of the instruction manual specifications. a c c e s s o r i e s www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide x state of the art microcontroller design x user friendly programming for on/off time selection up to 99 hrs 59 mins. x 7 segment display indication for channel & timing operation. x multiple units can be cascaded to obtain more channels. x program & process value retention incase of power failure. x external contacts for timing initiation & timing pause. x * olp=on line programming hold: when the slide switch on the front panel is kept in the hold position, the timing data is retained in case of power failure. upon resumption of power the timing continues from the point where it has stopped. restart: when the slide switch is kept in the restart position, the timer resets in case of power failure and starts from beginning upon power resumption. external start: by shorting terminals s1 and s2 for minimum period of 120 milliseconds (potential free shorting) or by keeping s1 and s2 permanently shorted, the timer sequence is initiated. single cycle operation: by keeping the terminals c1 and c2 shorted (potential free) on the front panel, the sequential switching of output is executed for one cycle and stops. cyclic operation : by keeping the terminals c1 and c2 on the front panel open, the sequential switching of outputs keeps repeating after the end of each cycle. inhibit: by shorting terminals i1 and i2 (potential free) on the front panel, status of relays/triac output (on or off) is maintained irrespective of the program timing. by removing the short, the programmed timing continues and relay / triac respond as per the preprogrammed timings. model function output source voltage time range ST-10 sequential switching with olp relay output relay 110v ac 240v ac 0.1 sec to 99 hrs 59 mins ST-10m1 sequential switching without olp relay output relay 110v ac 240v ac 0.1 sec to 99 hrs 59 mins st-6m1 6-channel sequential switching without olp relay output relay 110v ac 240v ac 0.1 sec to 99 hrs 59 mins ST-10m2 sequential switching without olp triac output triac 110v ac 240v ac 0.01 sec to 99 hrs 59 mins s a l i e n t f e a t u r e s o r d e r i n g i n f o r m a t i o n s p e c i a l f e a t u r e s www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide cycle complete output: this feature namely an opto coupled output signal from terminals o1 and o2 is available at the end of one switching sequence. this signal is intended for cascading one or more units to increase the number of output channels. online programming: this facility is provided only in model st10 wherein it permits the user to change the program online by setting the switches in ?prog? position making the required changes in timing and implementing the same, for the cycle in progress. operating instructions operating voltage range - 15% to + 10% of rated voltage rated frequency 50 hz r 5% power consumption 15v a / 3w ac approx. number of channels 10 (rlyo ?rly9) 10(op0 ? op9) for ST-10m2 6 (rlyo ?rly5) for st-6m1 on / off time range 0.1 sec to 99hrs 59mins. for each channel 0.01 secs to 99hrs 59mins. in st 10 m2 control output no relay contacts rated for 10a@ 250v ac/28v dc resistive for st 10 m1, st 6m1 for ST-10m2 10 triac output (op0 - op9) rated 500ma @ 250v ac resistive setting accuracy r 0.1% max w.r.t setting r 50msecs. r 0.2% max w.r.t setting r 20msecs for ST-10m2 repeat accuracy r 0.05% max r 50msecs. r 0.3% max. r 20msecs for ST-10m2 recovery time 2 secs min variation due to voltage change r 1% max r 50msecs. variation due to temp. change r 2% max r 50msecs. variation due to freq. change r 1% max r 50msecs. ambient temperature operating: - 10 q c to + 55 q c storage : - 25 q c to + 80 q c humidity max. 85% rh @ 40 q c electrical life 10 5 operations min. with full load rated frequency of operation 1800 r 5% operations per hour max. insulation resistance >100m ohms @ 500 vdc connections screw type terminals with self lifting clamps dimensions 200 x 130 x 45 mm [w x h x d] s p e c i f i c a t i o n s www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide x potential free contacts should be used to short terminals c1 & c2 ,i1 & i2, s1&s2.applying power to these points will damage the timer permanently. x when more than one unit is used in cascade, output o1 & o2 should be connected to s1 & s2 respectively of next timer. x do not connect o1& o2 to s1 & s2 of the same timer. use c1 & c2 for cyclic or single cycle mode operation. x programming is not possible if terminals i1 & i2 are shorted. x apply rated voltage to the timer to avoid permanent damage 1 sequence this button is used to select the required output / channel to program the timing. 2 on / off f r o n t p a n e l www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide this button is used to select the on time and off time for particular output / channel 3 range this button is used to select the desired time range (sec/sec, min/sec, and hrs/min) 4, 5 adv this buttons is used to increment the time range digits 6 prog/run this switch is used to select the mode of operation (for programming prog mode& for running timer run mode) 7 restart/hold this switch is used to select the restart or hold mode. 8 display it displays the relay number which is in function. 9, 14 indicator it is the indicator for on time and off time. 10, 11 & 12 indicators it indicates the different time combinations 13 displays it displays the time combination. 15 indicators it indicates the relay on function. a1, a2 : power s1, s2 : external start c1, c2 : single cycle or cyclic operation selection terminal (short single cycle, open for cyclic operation) o1, o2 : output for cascade mode operation i1, i2 : inhibit terminals rly0 to rly9 : normally open relay contacts (for st10, st10- m1) rly0 to rly5 : normally open relays contacts (for st6-m1) op0 to op9 : triac outputs (for st10-m2) t e r m i n a l d e t a i l s www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide note: in the above figure relay 9 is connected to the load, similarly other relays can be connected to load. c o n n e c t i o n d i a g r a m t i m i n g d i a g r a m www.datasheet.co.kr datasheet pdf - http://www..net/
sequential timer quick reference guide x keep the prog/run slide switch in the ?prog? position. x apply rated voltage across a1 and a2. x by using the ?sequence? button, select the required output, to program the timer. x by using the ?on / off? button, select the ?on ?and ?off? time for particular output. x by using the ?range ?button, select the desired time range (sec/sec or min/sec or hrs/min) as per requirement. x set the required time by using ?adv? button. x after programming the timer, keep the ?run/prog? slide switch in ?run? position and the unit is ready for operation. x by shorting the s1 and s2 terminals on the front panel for a minimum period of 150 milliseconds, the timing is initiated. x the sequence starts with closure of ?rly0/op1?as the case may be. x s1 and s2 can be kept permanently shorted to start the sequence when in hold mode. x in case of restart mode start signal is required every time a sequence has to be initiated. x short c1 and c2 of all the timers to be cascaded. x connect o1 and o2 of the first timer to s1 and s2 respectively of the second timer and so on. (o1s1 ? o2s2 and so on?.) p r o g r a m m i n g t h e t i m e r i n i t i a t i n g a s e q u e n c e t i m e r c a s c a d i n g www.datasheet.co.kr datasheet pdf - http://www..net/